Objective
This article is designed to condense common information into a single source and consolidate individual links from other articles; e.g., a quick reference guide. Information has been parsed from other knowledge-based articles, which may receive updates at any time.
Applies To
8x8 Work
8x8 Contact Center
8x8 Meetings
Agent Workspace
Network-Related Links and Information
DNS Options
Do not use Google DNS or OpenDNS.
When using recommended DNS options, if their ISP is not listed, they should contact their ISP about recommendations.
The 8x8 GTMs DNS should only be used if the physical phones are on either a dedicated VLAN or their own entire network with no other device (desktops, laptops, etc.) as they do not allow standard internet traffic and only VOIP/SIP traffic.
Meraki-Specific Settings
Make sure SRTP is set to enabled.
Hard code 8x8 GTM options anytime possible.
Force the phones to go over TLS.
Network Layout Template
ISP:
Make/Model gateway/modem: (If a gateway, is it in bridge mode or does it have a pinhole to the firewall?)
Make/Model Firewall/router:
Make/Model of any switch between firewall and phone:
Any additional servers that may be influencing traffic?
VLAN configurations: (Optional)
Is an SD-WAN (or Loop) being run between multiple sites? (Optional)
Is a VPN being used?
Are there any load balancers in place?
WinMTR or Ping Plotter
When running WinMTR or Ping Plotter make sure to check against all three of the following:
192.84.16.2 – West Coast
8.28.0.2 – East Coast
Local router private IP
Subnets to Whitelist, Allow, or Permit
United States Subnets
United States, Santa Clara Datacenter: 162.221.236.0/23
United States, Santa Clara Datacenter: 192.84.16.0/22
United States, Santa Clara Datacenter: 216.59.136.0/24
United States, Santa Clara Datacenter: 63.209.12.0/24
United States, Santa Clara Datacenter: 8.21.164.0/24
United States, Santa Clara Datacenter: 8.5.248.0/23
United States, SV2 Next Gen: 216.59.141.0/24
United States, Virginia Datacenter: 129.159.80.0/24
United States, Virginia Datacenter: 162.221.238.0/23
United States, Virginia Datacenter: 8.28.0.0/22
Note:
A complete list of updated subnets can be found in the X-Series Technical Requirements link. You can also find the 8x8 Meet subnets in this same documentation.
Canada Subnets
Canada Datacenter: 142.165.219.0/24
Canada Datacenter: 67.225.14.144/28
Montreal Datacenter: 168.138.74.128/26
Toronto Datacenter: 140.238.129.0/26
Note:
A complete list of updated subnets can be found in the X-Series Technical Requirements link. You can also find the 8x8 Meet subnets in this same documentation.
VO and VCC Ports to Open
TCP 636
TCP 5199
TCP 5401
TCP 5443
UDP 443
UDP 5060
UDP 5199
UDP 5299
UDP 5399
UDP 10000
UDP 24000-30999
UDP 38000-44999
UDP 50000-65535
Note:
A complete list of updated ports can be found in the X-Series Technical Requirements link.
Hardware-Related Links and Information
Fax Settings
Fax Speed or Baud Rate should be lowered to 9600bps.
Error Correction Mode (ECM) should be disabled.
Resolution should be Standard (not Fine, Ultrafine, Photo, etc.).
Overseas (International) Mode set to ON.
Set to Fax-Only mode.
Call Waiting must be disabled for the fax extension.
Various Hardware Tricks and Tips
For Obihai adapters, SRTP should be disabled.
For Audiocode adapters, SRTP should also be disabled.
For Audiocode adapters, it can sometimes take up to 15 minutes of rebooting before the Bootstrap.ini file completes its upload and provisioning. Let it sit for at least this long if experiencing issues.
Some Polycom devices are enabled with ZTP (Zero Touch Provisioning) but may experience issues and, if so, see Setting Up ZTP Override
Call Samples and Details
All call samples should be submitted within 24 hours or less of occurring. This allows us time to escalate them to our NOC, and if needed, our carriers.
Call Sample Template
TID: (If using VCC)
Location: (If multiple)
Date/Time of Call/Time Zone:
Duration of Call: (If applicable)
Call from: (Source number or extension)
Call To: (Destination number or extension)
Result: (Dropped call, garbled, etc.)